Cirurgia navegada dinâmica com X-Guide em caso Classe IV de Kan: relato de caso clínico

Carlos Breitenbach Scherer
Especialista em Implantodontia – Iodontus/RS; Mestrando em Implantodontia – SLMandic/ SP; Especialista em Prótese Dentária – Centro de Estudos Meridional; Professor dos cursos de cirurgia avançada – Implanto Excelência/CBS Biocare.
Orcid: 0009-0004-2476-1645.

Rafael Manfro
Mestre e doutor em Implantodontia; Coordenador do Grupo Implanto Excelência de Ensino em Cirurgias Avançadas para Implantodontia.
Orcid: 0000-0002-7431-0170.

Maurício Pereira da Rosa
Especialista em Ortodontia; Especialista e mestrando em Implantodontia – SLMandic; Professor dos cursos de cirurgia avançada Implanto Excelência/ Univali Be Dental School.
Orcid: 0000-0002-3895-5983.

Gustavo Vieira da Costa
Especialista em Radiologia e Imaginologia – Forp-USP; Mestre em Odontologia – FO-UFU.
Orcid: 0009-0003-5674-3217.

 

DOI: https://doi.org/10.71440/2675-5610.11.3.26.260-265.art

 

RESUMO

Paciente do sexo masculino, com 63 anos de idade, procurou o Centro de Pós-graduação em Odontologia CBS Biocare queixando-se de mobilidade no dente anterior. O exame clínico detectou boa estabilidade oclusal e uma faixa ampla de gengiva queratinizada na região anterior, porém havia comprometimento ósseo localizado, com o elemento 11 apresentando mobilidade grau 3 à percussão e extrusão devido à progressão da doença periodontal. Ainda, no exame por imagem, foi observada perda óssea generalizada e a presença do forâmen nasopalatino, evidenciando uma Classe IV de Kan et al5, portanto limitando a instalação de um implante imediato. Em seguida, um implante dentário (3,5 mm x 13 mm) foi planejado através de uma tomografia computadorizada de feixe cônico (TCFC), sendo virtualmente posicionado com o auxílio do software dedicado (DTX Studio Implant, Nobel Biocare), permitindo a definição ideal da sua posição tridimensional, sempre considerando a melhor posição protética. Após calibração e refinamento, foram seguidas as recomendações do fabricante para instalação do implante. O preenchimento dos espaços entre o implante e o alvéolo residual foi realizado com uma matriz inorgânica bovina associada à fibra de colágeno tipo I (Extra Graft XG-13). Finalmente, uma prótese provisória parafusada com pilar de titânio (transmucoso 3,5 mm) foi conectada. A TCFC pós-operatória evidenciou a precisão da técnica cirúrgica. Dentro dos limites deste relato de caso clínico, foi possível concluir que a cirurgia navegada dinâmica permite a instalação de implantes na posição protética correta, evitando o comprometimento de estruturas anatômicas, mantendo a segurança e gerando menor morbidade.

Palavras-chave – Implantes dentários; Navegação dinâmica; Técnica cirúrgica; Cirurgia guiada.

 

Dynamic navigated surgery using X-Guide in a Kan Class IV condition: a clinical case report

ABSTRACT

A 63-year-old male patient sought the CBS Biocare Dental Postgraduate Center complaining of mobility in an anterior tooth. Clinical examination detected good occlusal stability and a wide band of keratinized gingiva in the anterior region; however, there was localized bone compromise, with tooth #11 presenting Grade 3 mobility upon percussion and extrusion due to the progression of periodontal disease. Additionally, imaging examination revealed generalized bone loss and the presence of the nasopalatine foramen, evidencing a Class IV according to Kan et al, thereby limiting the placement of an immediate implant. Subsequently, a dental implant (3.5 mm x 13 mm) was planned through cone-beam computed  tomography (CBCT), being virtually positioned with the aid of dedicated software (DTX Studio Implant, Nobel Biocare), allowing the ideal definition of its three-dimensional position, always considering the best prosthetic position. After calibration and refinement, the manufacturer’s recommendations for implant placement were followed. The spaces between the implant and the residual socket were filled with an inorganic bovine matrix associated with type I collagen fiber (Extra Graft XG-13). Finally, a provisional screw-retained prosthesis with a titanium abutment (3.5 mm transmucosal) was connected. Postoperative CBCT evidenced the accuracy of the surgical technique. Within the limits of this clinical case report, it was possible to conclude that dynamic navigated surgery allows the placement of implants in the correct prosthetic position, avoiding compromise of anatomical structures, maintaining safety, and generating lower morbidity.

 

Keywords – Dental implants; Dynamic navigation; Surgical technique; Guided surgery.

 

Referências bibliográficas

  1. Emery RW, Merritt SA, Lank K, Gibbs JD. Accuracy of dynamic navigation for dental implant placement-model-based evaluation. J Oral Implantol 2016;42(5):399-405.
  2. Panchal N, Mahmood L, Retana A, Emery R 3rd. Dynamic navigation for dental implant surgery. Oral Maxillofac Surg Clin North Am 2019;31(4):539-47.
  3. Cunha RM, Souza FÁ, Hadad H, Poli PP, Maiorana C, Carvalho PSP. Accuracy evaluation of computer-guided implant surgery associated with prototyped surgical guides. J Prosthet Dent 2021;125(2):266-72.
  4. Choi W, Nguyen BC, Doan A, Girod S, Gaudilliere B, Gaudilliere D. Freehand versus guided surgery: factors influencing accuracy of dental implant placement. Implant Dent 2017;26(4):500-9.
  5. Kan JY, Roe P, Rungcharassaeng K, Patel RD, Waki T, Lozada JL et al. Classification of sagittal root position in relation to the anterior maxillary osseous housing for immediate implant placement: a cone beam computed tomography study. Int J Oral Maxillofac Implants 2011;26(4):873-6.
  6. Lopes A, Nobre MA, Santos D. The workflow of a new dynamic navigation system for the insertion of dental implants in the rehabilitation of edentulous jaws: report of two cases. J Clin Med 2020;9(2):421.
  7. Alkanderi A, Al Sakka Y, Koticha T, Li J, Masood F, Suárez-López Del Amo F. Incidence of nasopalatine canal perforation in relation to virtual implant placement: a cone beam computed tomography study. Clin Implant Dent Relat Res 2020;22(1):77-83.

 